Fluke 1773 Power Quality Analyser
The Fluke 1773 Three-Phase Power Quality Analyser eliminates the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the Fluke 1773 offers automatic measurements, a straightforward user interface and best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord.
With the Fluke 1773 you’ll never miss a critical power quality event—from dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system.
The Fluke 1773 is a 2-in-1 device that combines the troubleshooting functionality of a power quality meter with the robust analysis and logging of more than 500 power quality parameters in a single, easy-to-use, handheld device. The Fluke 1775 was designed to be safe and easy to use in any measurement environment.
The Fluke 1773 allows you to capture a full range of power quality variables as well as high-speed waveforms, and higher frequency harmonics, all of which are instantly viewable on the large, high-resolution screen. With a best-in-class CAT IV 600 V / CAT III 1000 V overvoltage rating, these analysers can be used at the service entrance or downstream, measuring AC and DC inputs, and harmonics measuring up to 30 kHz.
With the Fluke 1773 you can be confident that you'll capture the data you need to make better maintenance decisions no matter the task. The 'PQ Meter' function gives you immediate access to live onscreen data in the field so you can quickly identify potential problems while troubleshooting. The detailed 'PQ Logging and Analysis' function eliminates the complexity of performing power quality studies by guiding you through the setup process ensuring you're capturing the right data every time. Couple these measurement modes with a unique measurement connection autocorrect function and you can be confident that you never need to worry about going back for a second measurement.
The Fluke 1773 offers the best-in-class accuracy you've come to expect from a Fluke Power Quality Analyser in a IEC 61000-4-30 Class A edition 3 compliant package. On top of that, the 1775 Series has been engineered to meet the future requirements of Class A edition 4, for conformance to EN 50160 and IEEE 519.
Ideal for: Energy surveys and load testing, Harmonic surveys.
Fluke Premium Care Plan
The Fluke Premium Care Plan aims to reduce the cost of ownership of the Fluke 1773 Power Quality Analyser by eliminating service and support charges. Available as a one-year or three-year option, the Fluke Premium Care Plan includes one annual calibration per year at a Fluke Authorised Service Centre. If any accessories originally shipped with the Fluke 1773 Power Quality Analyser are defective, they will be replaced free of charge once a year under the Fluke Premium Care Plan. Accidental damage repair is also covered, providing peace of mind. With expedited calibration, repair, collection, and delivery, the Fluke Premium Care Plan minimises downtime. Simply check the one-year or three-year Fluke Premium Care Plan when placing your order, and your new Fluke 1773 Power Quality Analyser will be protected with Fluke Premium Care.
Fluke 1773 Three Phase Power Quality Analyser
Voltage inputs
Number of inputs - 4 inputs, 3 phases and neutral referenced to PE (5 connectors)
Measurement category - 1000 V CAT III / 600 V CAT IV
Maximum input voltage - 1000 V rms / 1000 V dc (1700 Vpk)
Nominal voltage range - Wye and single phase: variable (50 V – 1000 V)
Delta: Variable (100 V – 1000 V)
IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 V – 690 V
Input impedance - 10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE
Bandwidth - DC to 30 kHz for PQ measurements, excluding transients
Resolution - 24-bit synchronous sampling
Sampling frequency - 80 kS/s at 50/60 Hz
Scaling - 1:1, variable for use of potential transformers
Current inputs
Number of inputs - 4 inputs 3 phases and Neutral, range selected automatically to attached sensor
Range AC
1 A to 1500 A with i17XX-FLEX1500 12
1 A to 1500 A with i17XX-FLEX1500 18
1 A to 1500 A with i17XX-FLEX1500 24
3 A to 3000 A with i17XX-FLEX3000 24
6 A to 6000 A with i17XX-FLEX6000 36
40 mA to 40 A with clamp i40s-EL
4 A to 400 A with clamp i400s-EL
Range DC
20 A to 2000 A with 80i-2010-EL clamp
Bandwidth - DC to 30 kHz
Resolution - 24-bit synchronous sampling
Sampling frequency - 80 kS/s at 50/60 Hz
Scaling - 1:1, variable
Input voltage
Clamp: 50 mV / 500 mV rms; CF 2.8
Rogowski Coil: 15 mV / 150 mV rms at 50 Hz, 18 mV / 180 mV rms at 60 Hz; CF 4 all at nominal probe range
Input impedance - 11 kΩ
Data acquisition voltage and current
Input mains frequency - DC, 50/60 Hz 15 % (42.5 Hz … 57.5 Hz, 51 Hz … 69 Hz)
Topologies - 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye IT, 3-φ Aron/Blondel (2 element delta), 3-φ delta open leg, 3-φ high leg delta
Data storage - 8 GB microSD card (installed)
Memory size - Typical 10 logging sessions of 8 weeks with 1-minute intervals and 100 events.
The number of possible logging sessions and logging period depends on user requirements
Real time accuracy
Internal: 3 ppm (0.26 s per day, 8 s per month)
NTP (internet time): Depending on internet latency, typical < 0.1 s absolute to UTC
GPS: < 1 ms absolute to UTC
Trend interval
Trend interval - User selectable: 1 sec, 3 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Averaging interval min/max values - Voltage, Current: ½ cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 Hz) Aux, Power: 200 ms
Total harmonic distortion - THD for voltage and current is calculated on 50 harmonics
Power quality measurements
Harmonics:
h0 … h100
% fund and RMS for voltage, current and power
Phase angles for voltage and current up to h11
Interharmonics:
ih0… ih100
% fund and RMS for voltage and current
Supraharmonics:
2–9 kHz with 200 Hz bins
9–30 khz with 2 kHz bins
RMS for voltage and current
Harmonics measurement method - Grouped, sub-grouped and single harmonic bins according to IEC 61000-4-7.
Method selected automatically based on configured PQ standard or user configurable.
Total harmonic distortion - Calculated on up to 50 harmonics (depends on selected PQ standard)
Mains signaling - 2 frequencies in the range from 110 Hz to 3000 Hz
Events Voltage - Dip, swell, interruption, rapid voltage change, mains signaling, waveshape deviation, transients
Events Current - Inrush current
Triggered recordings
Half cycle RMS of voltage and current for 10 s
Waveform of voltage and current for 10/12 cycles
Mains signaling: 200 ms RMS of mains signaling voltage up to 120 s
1 x Fluke 1773 Power Quality Analyser
4 x i17XX-FLEX1500 18 Flexible CT
1 x FLUKE-17XX, Flat Cable, Voltage Test Lead 3-Phase+N
4 x Fluke AC285 Alligator Clip (Black)
1 x Fluke AC285 Alligator Clip (Green)
1 x USB-C Cable (1m)
1 x Line Cord
1 x FLK-17XX 0.18 M Test Lead Set, Nonstack/Stack
1 x Green Test Lead
1 x FLUKE-177X-4204 Wifi/BLE Module
1 x Cable Marker Set
1 x FLUKE-174X-MA-C8 Wall Outlet Adapter
1 x Statement of Calibration Practices