Fluke 175 Digital Multimeter
Fluke 175 True-RMS digital multimeter is the baseline for industrial measurements and safety rated for industrial use.
The Fluke 175 True-RMS Digital Multimeter delivers accurate true-RMS AC current and voltage plus frequency, capacitance, resistance, continuity and diode measurements. It increases productivity with manual and automatic ranging, display hold, Auto Hold, and Min/Max-average recording.
All inputs on the 175 are protected to IEN61010-1 CAT IV 600 V/CAT III 1000 V. UL, CSA, TÜV listed. You can rely on the Fluke 175 for accurate, true-RMS readings through years of reliable service.
The Fluke 175 digital multimeter has the features needed to find most electrical, electro-mechanical, and heating and ventilation problems.
Other useful features:
- Safety rated CAT III 1000 V, CAT IV 600 V
- Comes with a lifetime warranty
- Allows closed-case calibration through front panel
- Includes ergonomic case with integrated protective holster
Fluke 175 True RMS Multimeter
Voltage DC
Accuracy (1) - ±(0.15% + 2)
Max. resolution - 0.1 mV
Maximum - 1000 V
Voltage ACAccuracy (1) - ±(1.0% + 3)
Max. resolution - 0.1 mV
Maximum - 1000 VCurrent DC
Accuracy (1) - ±(1.0% + 3)
Max. resolution - 0.01 mA
Maximum - 10 A
Current ACAccuracy (1) - ±(1.5% + 3)
Max. resolution - 0.01 mA
Maximum - 10 A
ResistanceAccuracy (1) - ±(0.9% + 1)
Max. resolution - 0.1 Ω
Maximum - 50 MΩ
CapacitanceAccuracy (1) - ±(1.2% + 2)
Max. resolution - 1 nF
Maximum - 10,000 µF
FrequencyAccuracy (1) - ±(0.1% + 1)
Max. resolution - 0.01 Hz
Maximum - 100 kHz(1) Accuracies are best accuracies for each function
Environmental Specifications
Operating temperature - -10°C to +50°C
Storage temperature - -30°C to +60°C
Humidity (without condensation)
0% – 90% (0°C – 35°C)
0% – 70% (35°C – 50°C)
Safety Specifications
Overvoltage category
EN 61010–1 to 1000 V CAT III
EN 61010–1 to 600 V CAT IVAgency approvals - UL, CSA, TÜV listed
Mechanical and General Specifications
Size - 43 x 90 x 185 mm
Weight - 420 g
Warranty - Lifetime
Battery life - Alkaline ~200 hours typical, without backlight