Baur viola High-voltage test and diagnostics device
Cable testing and diagnostics with the BAUR viola
The portable and powerful viola high-voltage testing and diagnostics device is used for cable and cable sheath testing of medium-voltage cables up to 35 kV and electrical equipment. Another function is insulation testing on electrical equipment.
- High performance and compact
- Precise and non-destructive determination of the cable condition
- Easy and quick test setup
- Automatic testing and diagnostic sequences
The BAUR viola is used for the following
- testing medium-voltage cables and electrical equipment (generators, transformers and switchgear)
- for cable sheath testing
- Partial discharge measurement with PD-TaD 62
The VLF testing makes it possible to locate insulation faults in plastic- and paper-insulated mass-impregnated cables in the shortest of testing times without impairing the quality of the surrounding insulating material.
The dissipation factor diagnostics with 0.1 Hz VLF truesinus® provides differentiated information on the ageing condition of paper-insulated mass-impregnated and PE/XLPE cables. In the case of PE/XLPE cables, the dissipation factor measurement is capable of differentiating between new, slightly or severely “water tree”-damaged cables. This makes it possible to prioritise the need to replace cables.
Features
- Suitable for continuous operation
- Max. test voltage 44 kVrms / 62 kVpeak
- Voltage shapes: VLF truesinus®, VLF square wave voltage and DC voltage
- Load-independent, reproducible sinusoidal high voltage by means of VLF truesinus® testing technology
- Cable testing according to: IEC 60060-3, IEC 60502.2, CENELEC HD 620/621 (DIN VDE 0276-620/621), IEEE 400-2012, IEEE 400.2-2013
- Cable sheath testing according to IEC 60502/IEC 60229
- Can be expanded in combination with PD-TaD 62 to include the PD diagnostics function
Baur Viola High Voltage Test Set
- Viola VLF tester
- HV connection cable 10 m (fix mounted)
- GDR 80-272 discharge and earth rod
- Earth cable, 3 m, with earth terminal
- Jumper plug for external emergency off unit
- G-clamp, 45 mm
- Mains supply cord, 2.5 m
- User manual
- Pocket guide
Output voltage
Frequency range - 0.01 – 0.1 Hz
VLF truesinus® - 1 – 44 kVrms (62 kVpeak)
VLF square wave voltage - 1 – 60 kV
DC voltage (positive / negative) - 1 – 60 kV
Resolution - 0.1 kV
Accuracy - 1 %
Load range (VLF testing) - 1 nF – 10 μF
Output current
Measurement range - 0 – 70 mA
Resolution - 1 μA
Accuracy - 1%
Max. capacitive load -0.85 μF at 0.1 Hz, 44 kVrms / 62 kVpeak
2.7 μF at 0.03 Hz, 44 kVrms / 62 kVpeak
7.7 μF at 0.01 Hz, 44 kVrms / 62 kVpeakGeneral
Input voltage - 100 – 260 V, 50/60 Hz
Power consumption - Max. 1,400 VA
Reverse voltage protected - up to 13 kV
Degree of protection - IP21
Data interface - USB 2.0
Dimensions (W x H x D) excl. cable compartment
HV part - 505 x 503 x 405 mm
Operating unit - 505 x 433 x 405 mm
Total (two-part) - 505 x 854 x 405 mm
Weight
HV part - 57 kg
Operating unit - 19 kg
Ambient temperature (operational) - -10°C to +50°C
Storage temperature - -20°C to +60°C
Safety and EMC -
CE-compliant in accordance with
Low Voltage Directive (2014/35/EU),
EMC Directive (2014/30/EU),
EN 60068-2-ff Environmental testing